{"id":3499,"date":"2013-06-08T15:31:43","date_gmt":"2013-06-08T15:31:43","guid":{"rendered":"http:\/\/www.ikaa.com.my\/?page_id=3499"},"modified":"2017-12-15T07:39:18","modified_gmt":"2017-12-15T07:39:18","slug":"communication-modules-2","status":"publish","type":"page","link":"https:\/\/www.ikaa.com.my\/index.php\/fatek\/plc\/fbs-b1b1z-series\/communication-modules-2\/","title":{"rendered":"Communication Modules"},"content":{"rendered":"<div class='et-learn-more clearfix'>\n\t\t\t\t\t<h3 class='heading-more'>Fatek : PLC - Communication Modules<span class='et_learnmore_arrow'><span><\/span><\/span><\/h3>\n\t\t\t\t\t<div class='learn-more-content'><table border=\"0\">\n<tbody>\n<tr>\n<td style=\"width: 300px;\">\n<pre><span style=\"color: #808080;\"><span style=\"color: #ff9900; font-family: helvetica; font-size: small;\">Communication Modules\r\n\r\n<\/span><\/span><\/pre>\n<\/td>\n<td style=\"border: 1px solid #1006f8; width: 200px;\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n\t\t\t\t<\/div>\n<table style=\"width: 575px; height: 412px;\" border=\"0\">\n<tbody>\n<tr>\n<td style=\"width: 20px; text-align: center; background-color: #ff9900;\"><\/td>\n<td style=\"width: 570px; text-align: center; background-color: #ff9900;\"><span style=\"color: #ffffff; font-family: helvetica; font-size: small;\">Communication Modules<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #e6e6da;\"><\/td>\n<td style=\"background-color: #e6e6da;\">\n<pre><span style=\"font-family: helvetica; font-size: small;\"><span style=\"color: #0000ff;\">Model: B1-CM2<\/span><\/span><span style=\"font-family: helvetica; font-size: small;\">\r\n1 port RS232 (Port 2) communication module<\/span><\/pre>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #c5c5bc;\"><\/td>\n<td style=\"background-color: #c5c5bc;\">\n<pre><span style=\"font-family: helvetica; font-size: small;\"><span style=\"color: #0000ff;\">Model: B1-CM5<\/span><span style=\"color: #ffffff;\">\r\n1 port RS485 (Port 2) communication module<\/span><\/span><\/pre>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #e6e6da;\"><\/td>\n<td style=\"background-color: #e6e6da;\">\n<pre><span style=\"font-family: helvetica; font-size: small;\"><span style=\"color: #0000ff;\">Model: B1-CM22\r\n<span style=\"color: #000000;\">2 ports RS232 communication module<\/span><\/span><\/span><\/pre>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #c5c5bc;\"><\/td>\n<td style=\"background-color: #c5c5bc;\">\n<pre><span style=\"color: #ffffff; font-family: helvetica; font-size: small;\"><span style=\"color: #0000ff;\">Model: B1-CM55\r\n<\/span>2 ports RS485 communication module<\/span><\/pre>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #e6e6da;\"><\/td>\n<td style=\"background-color: #e6e6da;\">\n<pre><span style=\"font-family: helvetica; font-size: small;\"><span style=\"color: #0000ff;\">Model: B1-CM25<\/span>\r\n1 port RS232 (Port1) + 1 port RS485 (Port2) communication module<\/span><\/pre>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #c5c5bc;\"><\/td>\n<td style=\"background-color: #c5c5bc;\">\n<pre><span style=\"font-family: helvetica; font-size: small;\"><span style=\"color: #0000ff;\">Model: B1-CM25<\/span>\r\n<span style=\"color: #ffffff;\">1 port RS232 (Port1) + 1 port RS485 (Port2) + Ethernet <\/span><span style=\"color: #ffffff;\">network interface communication \r\nmodule<\/span><\/span><\/pre>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #e6e6da;\"><span style=\"font-family: helvetica; font-size: small;\">\u00a0<\/span><\/td>\n<td style=\"background-color: #e6e6da;\">\n<pre><span style=\"font-family: helvetica; font-size: small;\"><span style=\"color: #0000ff;\">Model: B1-CM55<\/span>\r\n<\/span><span style=\"font-family: helvetica; font-size: small;\">2 ports RS485 (Port1, Port2) + Ethernet network interface communication module<\/span><\/pre>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #c5c5bc;\"><span style=\"font-family: helvetica; font-size: small;\">\u00a0<\/span><\/td>\n<td style=\"background-color: #c5c5bc;\">\n<pre><span style=\"font-family: helvetica; font-size: small;\"><span style=\"color: #0000ff;\">Model: B1-CMZB<\/span>\r\n<span style=\"color: #ffffff;\">ZigBee communication module<\/span><\/span><\/pre>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Communication Modules Model: B1-CM2 1 port RS232 (Port 2) communication module Model: B1-CM5 1 port RS485 (Port 2) communication module Model: B1-CM22 2 ports RS232 communication module Model: B1-CM55 2 ports RS485 communication module Model: B1-CM25 1 port RS232 (Port1) + 1 port RS485 (Port2) communication module Model: B1-CM25 1 port RS232 (Port1) + 1 [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":781,"menu_order":0,"comment_status":"open","ping_status":"open","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.ikaa.com.my\/index.php\/wp-json\/wp\/v2\/pages\/3499"}],"collection":[{"href":"https:\/\/www.ikaa.com.my\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.ikaa.com.my\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.ikaa.com.my\/index.php\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ikaa.com.my\/index.php\/wp-json\/wp\/v2\/comments?post=3499"}],"version-history":[{"count":2,"href":"https:\/\/www.ikaa.com.my\/index.php\/wp-json\/wp\/v2\/pages\/3499\/revisions"}],"predecessor-version":[{"id":3503,"href":"https:\/\/www.ikaa.com.my\/index.php\/wp-json\/wp\/v2\/pages\/3499\/revisions\/3503"}],"up":[{"embeddable":true,"href":"https:\/\/www.ikaa.com.my\/index.php\/wp-json\/wp\/v2\/pages\/781"}],"wp:attachment":[{"href":"https:\/\/www.ikaa.com.my\/index.php\/wp-json\/wp\/v2\/media?parent=3499"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}